Celebrating 20 years
in business.
Building solutions and satisfying our customers, one at a time!
C&L Awarded US Patent
No. 7,245,368
Sample Chamber for Microscopy
Innovative sample chamber design hold
coverslips using a vacuum force. Coverslips attach leak-free, without
breakage and in seconds to create a laminar flow chamber.

C&L
Instruments manufactures fluorometers and fluorometer components for steady-state
fluorescence measurements. We offer complete fluorescence systems for
your microscope for
photometry measurement. We also offer cuvette-based
fluorometers, illumination sources, photon-counting detectors and numerous
handy accessories. Also be sure to examine our new line of microscope
perfusion chambers.
|
| |
New Products

What's New at C&L
-
New Mini Series
Perfusion chambers are available. The
Mini Series Thin Window chamber
forms a 100 micron thick chamber with one body part and two
coverslips!
-
NEW 3D Interactive Model!
-
New
C-Mount photomultiplier detectors, Models DPC-BA and DPC-MA provide
simple and cost effective photometry. See
them here.
-
Incubate
coverslips in standard fluorescence cuvettes using our CCH-1 and CCH-2
inserts. Very nice.
New FluorMeasureTM Software allows for:
-
external
data acquisition triggering.
-
data
synchronization with electrophysiology systems.
-
time-lapse
fluorescence measurements. See
details!
-
Measure O2
consumption simultaneously with fluorescence.
Details here.
Browse
our web site to learn more about our unique fluorescence systems.
Our
fluorometers are:
Versatile. The components of our fluorometer systems are modular.
They can interchangeably connect to a fluorescence microscope, a cuvette accessory,
or a surface fluorescence probe.
Sensitive and have low
noise. Our fluorometers are entirely
digital. We use end-on photon-counting PMT's for high sensitivity, wide dynamic range and
low noise.
Multiwavelength. Select up to eight excitation and eight emission
wavelengths for measurement of nearly any fluorescent probe or probe combination.
You can use both excitation and emission wavelength-shift probes (fura-2, BCECF,
indo-1, etc.) in several combinations. Our imaging system also supports imaging
at eight wavelengths!
Fast. You can acquire up to eight
excitation-emission wavelength pairs in 8 milliseconds (1 KHertz/wavelength
pair) with our photometry systems.
Fluorescence ratios (fura-2, indo-1, etc.) can be measured at 0.5 KHertz, continuously
(500 ratios/sec).
Plug and
Play. No optical alignment required. Just plug it in and
collect data.
Economical. Our systems offer more, but cost much less.

Please browse our web site,
review our products, see how our systems are integrated and download our specification
sheets and software. Do not hesitate to contact us!
We would be pleased to help you solve your application needs.
|