The
Model DPC-BA & DPC-MA Detector Modules are complete detector
assemblies that contain a photon-counting photomultiplier tube in a
compact enclosure with C-mount threads for easy microscope mounting. The
Detector Module is designed for high-sensitivity photometry
detection. Light enters the Detector Module directly through a
C-mount adapter. The C-mount adapter may be directly coupled to a
microscope or attached to a fiber optic light guide. The light guide
provides maximum flexibility for interfacing the detector to a cuvette
assembly, a surface fluorescence probe or other custom user-specific
devices. The detector output can be coupled to the Model
DPC or PC-DAQ Controllers which reside in
your PC. Together with our FluorMeasureTM
software, the unit performs sensitive photon counting detection.
The
Model DPC-BA and DPC-MA Detector Modules can be purchased as part of a
complete fluorometer / photon-counting system or separately to serve as a
stand-alone detection system. They can also be added to fluorescence
imaging systems to provide a faster and more sensitive means of
fluorescence detection and quantitation. A calibrated iris is
included to adjust the input light level. The mount also includes a
threaded holder for 1" or 25mm optics or filters. Other mounts are
also available.
Connections
to the Detector Module are made from the back of the assembly. A BNC
connector provides TTL output pulses for easy interface to our Model
PC-DAQ controller or our Model
DPC Digital Photon Counting System. The Detector Module is
powered by a +5 Volt supply which is included.
Features
- High sensitivity PMT detection
system in a C-mount package.
- Readily connects to microscopes or
fiber optic adapters.
- Internal Iris/shutter is included.
- Holds 1 inch/25 mm diameter optical
filter.
- Single +5 Volt external power
supply included.
- Low cost.
- Available with
Bialkali and Multialkali PMT tubes.
Specifications
- Size: (l) 10 ½ " (267mm)
X (d) 2.2" (56mm)
- Weight: Approximately 1.5 lbs
- Power Requirement: 5V DC wall
mount regulated supply (included)
- PMT: DPC-BA 1 inch diameter
end-on shielded BiAlkali for 280-630 nm range, max QE: 28%; DPC-MA 1
inch diameter end-on shielded Multialkali for 280-850 nm range, max
QE: 21%
- PMT Window: Borosilicate glass
(Fused Silica and UV Quartz available by special order)
- PMT high voltage power source:
Internal power supply.
- Optical Interface: C-Mount
threaded adapter (internal threads) standard, other configurations
available.
- PMT output: BNC connector,
Positive TTL logic (Photon counts).
|